Slot and pole explorer

Choose a slot count and a pole count for a three-phase machine and see the winding it gives, its winding factor and the harmonics of its stator field.

phase Aphase Bphase CN poleS pole

Slots per pole per phase
2/5
Winding factor
0.933
Coil span
1 slot
Cogging cycles per turn
60
Lowest radial force order
2
Winding repeats
1 time

Winding layout

Stator MMF harmonics

turns with the rotorturns against it

What the numbers mean

  • Slots per pole per phase: slots divided by (poles × 3). If it is not a whole number the winding is a fractional slot winding. With a coil span of one slot each coil is wound around a single tooth.
  • Winding factor: the vector sum of the coil-side EMFs of one phase divided by their arithmetic sum, for the working harmonic. It includes the distribution and pitch factors.
  • Cogging cycles per turn: the least common multiple of slots and poles. The cogging torque repeats every 360° divided by this number.
  • Lowest radial force order: the greatest common divisor of slots and poles. A value of 1 means the radial forces do not cancel around the air gap.
  • Winding repeats: the greatest common divisor of slots and pole pairs, which is how many identical sections the winding has.
  • Stator MMF harmonics: the bar for a harmonic with h pole pairs is its winding factor divided by h, as a percentage of the same quantity for the working harmonic. The number under each bar is h.

How it works

The winding is a double-layer winding laid out by the star of slots: one coil starts in every slot, and each coil goes to the phase whose 60° belt its EMF phasor falls in. In the layout, a capital letter is a coil side carrying current toward you at positive phase current, and a small letter is one carrying it away.

In the picture each slot holds two coil sides in the colour of their phase, lighter where the current returns. With the rotor spinning, it turns in the direction of the working harmonic and moves one pole pair per electrical cycle, so a machine with more poles turns slower at the same frequency.

Limitations

Only three-phase, double-layer windings are covered. The currents are ideal sine waves, and slot openings, saturation, skew and the rotor's own harmonics are not modelled. A combination that looks good here still has to be checked with FEA.